| Table of Contents | ||||
|---|---|---|---|---|
|
TR-069 is a technical specification that defines an application layer protocol for remote management of end-user devices. It was published by the Broadband Forum and was entitled CPE WAN Management Protocol (CWMP). It provides the communication between CPE and Auto Configuration Servers (ACS). An ACS can manage a device, trouble shoot, configure, upgrade etc. TR-69 uses common web protocols such as HTTP, TCP-IP, SOAP, XML-RPCs to exchange information.
...
Ensure the GenieACS Server Setup is launched and running to establish the Client-Server communication
GenieACS server home page:
Steps to be followed:
1) Flash the RDK-Broadband image where the Tr069 Protocol Agent is enabled.
...
2) Check for the CcspTr069PaSsp is active and listening to port 7547
3)Then, set the parameters for connecting CPE with ACS server.
| Code Block | ||||||
|---|---|---|---|---|---|---|
| ||||||
$ dmcli eRT setv Device.ManagementServer.EnableCWMP bool true $ dmcli eRT setv Device.ManagementServer.URL string http://192.168.2.165:7547/ $ dmcli eRT setv Device.DeviceInfo.X_RDKCENTRAL-COM_Syndication.TR69CertLocation string "/etc/cacert.pem" |
4) Following are the parameters needed to be checked for TR69.
Parameter Name | Expected Value |
|---|---|
| Device.ManagementServer.EnableCWMP | true |
| Device.ManagementServer.URL | ACS Server URL: http://192.168.2.165:7547/ |
| Device.DeviceInfo.X_RDKCENTRAL-COM_Syndication.TR69CertLocation | /etc/cacert.pem |
5) Now, from the GenieACS Server try to fetch the Connected Devices details.
...