Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Ensure the GenieACS Server Setup is launched and running to establish the Client-Server communication
GenieACS server home page:

Image RemovedImage Added

Test Procedure

...

  1. Flash the RDK-Broadband image where the Tr069 Protocol Agent is enabled

  2. Check for the CcspTr069PaSsp is active and listening to port 7547



  3. Then, set the parameters,

    Code Block
    languagebash
    themeDJango
    $  dmcli eRT setv Device.ManagementServer.EnableCWMP bool true
    
    $  dmcli eRT setv Device.ManagementServer.URL string http://17210.2078.10151.11540:7547/
    
    $  dmcli eRT setv Device.DeviceInfo.X_RDKCENTRAL-COM_Syndication.TR69CertLocation string "/etc/cacert.pem"


    Following are the parameters needed to be checked for TR69

    Parameter Name Expected Value
    Device.ManagementServer.EnableCWMPtrue
    Device.ManagementServer.URLACS Server URL:  http://17210.2078.10151.11540:7547/
    Device.DeviceInfo.X_RDKCENTRAL-COM_Syndication.TR69CertLocation/etc/cacert.pem

    Now, from the GenieACS Server try to fetch the Connected Devices details

...