Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.

...

Ensure the GenieACS Server Setup is launched and running to establish the Client-Server communication
GenieACS server home page:

Image RemovedImage Added

Test Procedure

...

  1. Flash the RDK-Broadband image where the Tr069 Protocol Agent is enabled

  2. Check for the CcspTr069PaSsp is active and listening to port 7547



  3. Then, set the parameters,

    Code Block
    languagebash
    themeDJango
    $  dmcli eRT setv Device.ManagementServer.EnableCWMP bool true
    
    $  dmcli eRT setv Device.ManagementServer.URL string http://17210.2078.10151.11540:7547/
    
    $  dmcli eRT setv Device.DeviceInfo.X_RDKCENTRAL-COM_Syndication.TR69CertLocation string "/etc/cacert.pem"


    Following are the parameters needed to be checked for TR69

    Parameter Name Expected Value
    Device.ManagementServer.EnableCWMPtrue
    Device.ManagementServer.URLACS Server URL:  http://17210.2078.10151.11540:7547/
    Device.DeviceInfo.X_RDKCENTRAL-COM_Syndication.TR69CertLocation/etc/cacert.pem

    Now, from the GenieACS Server try to fetch the Connected Devices details

...

  1. Visit the GenieACS Server page

  2. Click on "Devices" that displays the connected devices information and the device parameters available


Limitations

Only Basic connection communication has been establishedenabled, GPV, SPV, GPN and others will be achieved further