RDK Resources
[*RDK Preferred*]
Code Management Facility
RDK Forums
[RDK Conferences]
RDK Support
Archives
Papers & Presentations Archive
...
Using the below url to view the JSON Format result of http protocol ,
http://35.155.171.121:9092//xconf/swu/stb?eStbMac=<RPI MAC ADDRESS>&model=<model_name>&capabilities=RCDL&capabilities=supportsFullHttpUrl
1. Select Download Location filter under the firmware tab in XCONF UI
2. Click the edit button
3. Added the model name under the Rogue Model .
4. Click the save button.
Verify the tftp folder location:
amrita@amrita-OptiPlex-9020:~/tftphome$ pwd
/home/amrita/tftphome
that XConf Server configuration displays the Json response from the mentioned URL:
Using the below url to view the JSON Format result of http protocol ,
http://35.155.171.121:9092//xconf/swu/stb?eStbMac=<RPI MAC ADDRESS>&model=<model_name>&capabilities=RCDL&capabilities=supportsFullHttpUrl
4. Verify that image file and its respective md5 checksum file is present in the tftp http folder:
amrita@amrita-OptiPlex-9020:~/tftphome$ keerthana@keerthana-INVALID:/var/www/html$ ls
rdkb-generic-broadband-image_default_2019081207441220200529140558.rootfs.rpi-sdimg
folder rdkb-generic-broadband-image_default_2019081207441220200529140558.txt
5. Start tftp server and xinetd:
sudo service tftpd-hpa restart
/etc/init.d/xinetd restart
...
...
...
Note : 1. RPI will go for reboot while booting for the first time, since two more partition needs to be created which requires reboot. Depends on the image present in xconf and RPI, further reboot will happen for upgrade. Please refer to design (RDKB RPI Firmware Upgrade with support of HTTP protocol - Design - 2019 M72020 M6) for how firmware upgrade works with bank switching
...
3. If the user wants to view swupdate.log file then follow below steps:
a) Disable log rotation feature - This wipes out the log file if size exceeds after 1min
For B image command - systemctl disable rdkbLogMonitor
For V image command - systemctl disable logrotation.service
b) Reboot the box - This will make swupdate.service restart and user can start getting swupdate.log both for B and V image
4. Download of Video image(size 592 MB) takes roughly 40 min time and Broadband(size 292MB) image takes roughly 20 min time from Cloud server(Xconf). Broadband to Video or Video to Broadband is taking approx 15 min time to boot up after download from XConf server is completed.
5. Minimum extended partition should be 1GB, to verify multiboot firmware feature.