Architecture & Set-up

Device run-times

Related RFC

Device.DeviceInfo.X_RDKCENTRAL-COM_RFC.Feature.DAB.Enable

How to check current RFC configuration:

tr181 -g Device.DeviceInfo.X_RDKCENTRAL-COM_RFC.Feature.DAB.Enable

How to set the RFC:

tr181 -s -t boolean -v true Device.DeviceInfo.X_RDKCENTRAL-COM_RFC.Feature.DAB.Enable

How to clear the RFC:

tr181 -s -t boolean -v false Device.DeviceInfo.X_RDKCENTRAL-COM_RFC.Feature.DAB.Enable

Common pit-falls

  • How to get Device ID: Device ID which need to be supplied to the dab-compliance-suite to connect with dab-adapter instance running on the device can be obtained from dab-adapter start-up log.

    journalctl -fu dab-adapter
    root@AmlogicFirebolt:~# journalctl -fu dab-adapter
    -- Logs begin at Mon 2023-09-11 16:32:00 UTC. --
    Sep 11 16:35:05 AmlogicFirebolt systemd[1]: Started DAB <-> RDK adapter.
    Sep 11 16:35:05 AmlogicFirebolt dab-adapter[22887]: Monitoring changes of /run/dab-enable
    Sep 11 16:35:06 AmlogicFirebolt dab-adapter[22887]: DAB Device ID: AC64CF339B28
    Sep 11 16:35:06 AmlogicFirebolt dab-adapter[22887]: Ready to process DAB requests
    Sep 11 16:35:33 AmlogicFirebolt dab-adapter[22887]: OK: operations/list