RDK Resources
[*RDK Preferred*]
Code Management Facility
RDK Forums
[RDK Conferences]
RDK Support
Archives
Papers & Presentations Archive
Release Notes
RDKM Coverage Test cases (RDK-V)
Version: 25.0
05 April 2024
Revision History
Revision No. | Date | Revision Description |
1.0 | 03 Dec 2021 | |
2.0 | 10 Jan 2022 | 2nd Revision |
3.0 | 14 Feb 2022 | 3rd Revision |
4.0 | 14 March 2022 | 4th Revision |
5.0 | 25 May 2022 | 5th Revision |
6.0 | 20 June 2022 | 6th Revision |
7.0 | 11 July 2022 | 7th Revision |
8.0 | 12 August 2022 | 8th Revision |
9.0 | 31 January 2023 | 9th Revision |
10.0 | 28 February 2023 | 10th Revision |
11.0 | 31 March 2023 | 11th Revision |
12.0 | 01 May 2023 | 12th Revision |
13.0 | 12 June 2023 | 13th Revision |
14.0 | 07 July 2023 | 14th Revision |
15.0 | 04 Aug 2023 | 15th Revision |
16.0 | 06 Sept 2023 | 16th Revision |
17.0 | 06 Oct 2023 | 17th Revision |
18.0 | 06 Nov 2023 | 18th Revision |
19.0 | 29 Dec 2023 | 19th Revision |
20.0 | 08 Feb 2024 | 20th Revision |
21.0 | 06 March 2024 | 21st Revision |
22.0 | 05 April 2024 | 22nd Revision |
This Release Notes document has details on the delivery of 10 testcases of 6 1DOTO test cases and 4 3DOTO testcases.
Features Covered : TELEMETRY, VIDEO, SYSTEM
Following automatics 1.0 test cases are included in this release.
SI.No. | Automation Id | Steps | Summary | Feature |
---|---|---|---|---|
1 | TC-AV-1001 | 6 | Test case to verify dirty/clean status of a device in the warehouse. | VIDEO |
2 | TC-AV-4000 | 7 | Test To Validate the Telemetry request being sent. | VIDEO |
3 | TC-AV-5018 | 6 | Verify that invalid input arguments are not accepted by cgi-bin scripts. | VIDEO |
4 | TC-AV-1002 | 4 | Test to verify AV on HDMI connection when resolution is changed from 480p to 1080i and zoom is none. | VIDEO |
5 | TC-SETTINGS-5000 | 6 | Verifying the crash status when Resolution changing | SYSTEM |
6 | TC-SETTINGS-5001 | 6 | Test script for verifying AV after the Resolution change | SYSTEM |
Following automatics 3.0 test cases are included in this release.
SI.No. | Automation Id | Steps | Summary | Feature |
---|---|---|---|---|
1 | 3DOTO- TC-TELEMETRY-V2-RDKV-003 | 6 | Different ReportingIntervals and ActivationTimeOut check | TELEMETRY |
2 | 3DOTO- TC-TELEMETRY-V2-RDKV-004 | 7 | Same ReportingIntervals and ActivationTimeOut check | TELEMETRY |
3 | 3DOTO- TC-TELEMETRY-V2-RDKV-018 | 8 | Profile persist after Reboot | TELEMETRY |
4 | 3DOTO-TC-TELEMETRY-RDKV-1034 | 10 | Test to verify non-root privileges in RBUS mode | TELEMETRY |