Sanity Test cases :
S.No | Sanity tested on | Status |
|
---|
S.No | Sanity tested on | Status |
|
---|
1 | Image should be stable | Pass |
|
2 | OpenSync service and its manager should be running | Pass |
|
3 | RPI Extender onboarding over Wi-Fi | Pass |
|
4 | Able to Ping www.google.com from RPI Extender | Pass |
|
5 | Wifi Extension of Internet to mobile from GW | Pass | Currently through 2.4GHz Radio, While 5GHz radio is used for backhaul connectivity |
Validation:
- Able to connect client to TURRIS GW as well behind RPI4 extender.
- Able to witness GW and Extender availability in Plume Open Sync NOC.
- Also, able to browse the internet successfully.
- Client ping test for 4hrs passed.
Known issues/Observations:
- Due to Wi-Fi dongle's limited capability, using 5GHz radio for backhaul connectivity and 2.4GHz radio for Home AP
- Backhaul to GW is established only using 5GHz station interface but not using 2.4GHz station interface
- Could not connect mobile with 5GHz Home AP since 5GHz radio station interface is used for backhaul connectivity (may be due to hardware )
- Extender's (2.4GHz)HomeAP channel number is not matching with GW's (2.4GHz)HomeAP channel number (need to check plume cloud team)
OVSDB Tables:
Associated Clients:
AWLAN_Node:
Cloud Status:
Ping test:
ovs-vsctl show:
- GRE Tunnel needs to be formed for wifi-backhaul using opesync backhaul credentials(UPDATE 0001-Update-bhaul-credential.patch in meta-cmf-broadband layer)
- open sync mandates OVS-Switch and GRE backhaul entry can be found using "ovs-vsctl show"