You are viewing an old version of this page. View the current version.

Compare with Current View Page History

« Previous Version 11 Next »

This Page is under Development

Introduction

  • Webpa is a combination of a server and client that provide a simple interface to access the TR-181 objects on an RDK device.
  • It is a secure web protocol messaging system for bi-directional communication.

Environment Setup

  • Set-up Considerations

           On the WebPA Server and Client side ensure the following services.

1. Talaria: Talaria Service connects with the client and retrieves the data according to the user request.

2. Scytale: This service acts as a communication bridge between Talaria and Tr1d1um which is highly helpful in transmitting the data.

3. Tr1d1um: This receives the requests from the external resources, encryts it and send it Scytale.

On client-side

4. Parodus: Parodus is the light weight client that reaches out to the xmidt cloud to establish the connection from CPE devices.

   Additional Services:

5. Petasos : Petasos helps reduce the load on the Talaria machines by calculating which specific Talaria a device should connect to & redirecting the incoming request.

6. Caduceus: Caduceus provides the pub-sub message delivery (notification) mechanism for xmidt

  • User Access Considerations

1. The mentioned sevices need to be actively running with the basic key authorization.

2. Auth token: The auth token will be used when configuring different webPA components as well while performing GET/SET requests to the CPE from a 3rd party application.

3. Make ServerURL changes in the script file of client service, /lib/rdk/parodus_start.sh

4. Run the below commands

     rm -rf /tmp/parodusCmd.cmd

     systemctl restart parodus


  • Accessing the System

Once the Turris-Omnia set-up is active with client services, communication between turris and WebPA server can be established.

  • System Work Flow

The following are the major components/services involved in the fetching the data,

  • Exiting the System

         The validation artifacts that are essential to ensure the functionality,

    • Authorization Key
    • WebPA Server details(IP, Port number)
    • CPE Device mac address

    • Data Parameters(Specific details that need to be retrieved)

Executing System

The data from the client device can be fetched through the curl commands,

  • Curl command to retrieve the data(get parameter):

curl -H 'Authorization:Basic dXNlcjp3ZWJwYQo=' -i 'http://192.168.2.75:9003/api/v2/device/mac:d858d700a5d6/config?names=Device.Users.User.3.X_CISCO_COM_Password'

Response Message:

{"parameters":[{"name":"Device.Users.User.3.X_CISCO_COM_Password","value":"b1be9cacbfaf0d9d1b633915e8ed0259753057a0a10853a414947d6c27d074c1","dataType":0,"parameterCount":1,"message":"Success"}],"statusCode":200}

  • Curl command for the set operation:

curl -X PATCH http://192.168.2.75:9003/api/v2/device/mac:d858d700a5d6/config -d '{"parameters": [{"dataType": 0,"name":"Device.Users.User.1.X_CISCO_COM_Password","value":"Testing123"}]}' -H 'Authorization:Basic dXNlcjp3ZWJwYQo='

Response message:

{"parameters":[{"name":"Device.Users.User.1.X_CISCO_COM_Password","message":"Success"}],"statusCode":200}


Console Output Screenshot:


Generic Data Parameters: Get Only

i. Device.DeviceInfo.Manufacturer

ii. Device.DeviceInfo.ManufacturerOUI

iii. Device.DeviceInfo.ModelName

iv. Device.DeviceInfo.SerialNumber

v. Device.DeviceInfo.HardwareVersion

vi. Device.DeviceInfo.SoftwareVersion

vii. Device.DeviceInfo.UpTime

viii. Device.DeviceInfo.MemoryStatus.Total

ix. Device.DeviceInfo.MemoryStatus.Free

x. Device.DeviceInfo.ProcessStatus.CPUUsage

xi. Device.Hosts.X_CISCO_COM_ConnectedDeviceNumber

Set/Get Parameters:

i. Device.WiFi.SSID.10001.SSID

ii. Device.WiFi.SSID.10001.Enable

iii. Device.WiFi.Radio.10000.EnableDevice.WiFi.Radio.10000.Channel

iv. Device.WiFi.AccessPoint.10001.Security.KeyPassphrase

v. Device.Users.User.3.X_CISCO_COM_Password

Troubleshooting

  • Error Messages

Following are the error message that user may taken into considerations:

1. "message":"Invalid parameter value"}],"statusCode":520

For Invalid parameter value, check for correct parameter name and the unwanted space in the command

2. "message":"Error unsupported namespace","statusCode":520

For Unsupported namespace, check for the respective services that are essential to fetch tha data. For example, WiFi related information can be accessed only if ccspwifiagent service is active.

3. "message":Service Unavailable", "statusCode":531

For this error, ensure the network connection and the server and client-side services are up.


  • Special Considerations


Support

Contact

Organization

Phone

Email

Role

<Contact Name>

<Organization>

<Phone>

<Email>

<Role>

  • No labels